问题描述
在SAP系统的RFC接口结构中添加了字段,RFC也重新引用到了PO系统,Cache和CommunicationChannel都刷新或启停了,但是新增的字段在调用接口的时候数据进不到SAP系统,SAP系统内的值也出不来。经过多方排查,找到了在不重启PO服务器的情况下解决的方法。这个解决方法应该针对7.5 SP24及以上版本的系统,下面版本的接口调整应该常规刷新就可以了
SAP PI7.50 SP24 needs restart after imported RFC has been modified
Dear experts,
since migrating to PI7.50 (currently 7.50SP24) I see a strange behaviour when we modify RFC structures (e.g. adding a new field).
I import the definition from our ECC dev system and transport in test environment.
In the test environment I see the new structure in ESB. However when testing, the new field values are not handled in runtime.
I restarted XPI Adapter RFC, I did cache refreshes (CPA and Mapping Runtime) . That does not help. However when I completly restart the PI system, the new structure work.
What do I miss after transport so we don’t need to restart the entire system whenever we modify RFC structures?
best regards
解决办法
With 7.50 SP24, there is a fairly major change impacting on RFC integrations. Refer to the notes below from further information.
3147820 PI RFC Adapter using JCo3
3309842 RFC Adapter JCo3: RFC Metadata Not Updating
99%的人还看了
相似问题
- 基于ASP.NET MVC技术的图书管理系统的设计与实现
- MySQL数据库:开源且强大的关系型数据库管理系统
- 最新AIGC创作系统ChatGPT系统源码,支持最新GPT-4-Turbo模型,支持DALL-E3文生图,图片对话理解功能
- 基于springboot实现班级综合测评管理系统项目【项目源码+论文说明】
- 香港科技大学广州|机器人与自主系统学域博士招生宣讲会—同济大学专场!!!(暨全额奖学金政策)
- 合肥中科深谷嵌入式项目实战——基于ARM语音识别的智能家居系统(三)
- 基于Springboot的美容院管理系统(有报告)。Javaee项目,springboot项目。
- MES系统管理范围及标准
- 性能测试:系统架构性能优化思路
- django+drf+vue 简单系统搭建 (3) - 基于类的视图
猜你感兴趣
版权申明
本文"SAP POorPI RFC接口字段调整后需要的操作-针对SP24及以后的PO系统":http://eshow365.cn/6-23121-0.html 内容来自互联网,请自行判断内容的正确性。如有侵权请联系我们,立即删除!